Reverse Osmosis System Tank 20G Steel (74 Liter) ⅜

Total Operating Weight (Tank + Water)

Tank Model Dry Weight (Empty) Approx. Water Weight Total Weight (Full)
12 Litre ~4.0 kg + 8.0 kg ~12.0 kg
24 Litre ~6.5 kg + 16.0 kg ~22.5 kg
40 Litre ~9.8 kg + 28.0 kg ~37.8 kg
74 Litre ~14.5 kg + 50.0 kg ~64.5 kg

Installation Safety Warnings:

  • For the 12L & 24L Models: Most kitchen cupboards can handle these weights (12–23 kg) on the base floor. However, do not place a full 24L tank on a middle shelf without reinforcing it, as the shelf may bow or collapse over time.

  • For the 40L & 74L Models: These are very heavy (up to 65 kg). They should always be placed on a solid concrete floor or a reinforced steel stand.

  • Pressure Matters: If the customer’s RO system has a high-pressure pump, the tank might hold slightly more water than listed, making it even heavier. Always calculate for a “worst-case” maximum weight.

 

 

Description

Stainless Steel RO Storage Tank – 74 Litre

ID: 1163 | SKU: TQA.TANK.SS74

  • Total Volume: 74 Litres (approx. 20 Gallons)

  • Actual Water Capacity: ~50 Litres (at standard 40-60 PSI)

  • Connection: 1″ NPT Male Thread (Requires reducer for RO tubing)

  • Dimensions: 780mm (Height) x 380mm (Diameter)

  • Weight: ~14.5 kg

  • Best For: High-demand industrial applications, large-scale hydroponics, and whole-house RO backup.

    • Empty Tank Air Pre-Charge Requirements

      Tank Size Recommended Air Pressure (Empty) Maximum Working Pressure
      12 Litre 0.45 bar (approx. 7 PSI) 6.9 bar (100 PSI)
      24 Litre 0.45 bar (approx. 7 PSI) 6.9 bar (100 PSI)
      40 Litre 0.50 bar (approx. 8 PSI) 6.9 bar (100 PSI)
      74 Litre 0.55 bar (approx. 8 PSI) 6.9 bar (100 PSI)

       

    • Isolate & Empty: Turn off the water supply to the RO system and open the RO faucet until the water stops flowing completely. This ensures there is no back-pressure from the water.

    • Locate the Valve: On the side or bottom of the stainless steel tank, there is a small plastic cap. Unscrew it to reveal a standard Schrader Valve (exactly like a car or bicycle tire valve).

    • Check Pressure: Use a low-pressure digital gauge. If it reads $0$, the bladder has lost its charge.

    • Pump Slowly: Use a manual bicycle pump or a small compressor.

      • Warning: Only add a few pumps at a time. Because the air chamber is small, the pressure rises very quickly.

    • Target: Aim for 0.45 bar. If you go over, simply bleed a little air out using the center pin of the valve.