{"id":1185,"date":"2025-06-17T04:58:50","date_gmt":"2025-06-17T04:58:50","guid":{"rendered":"https:\/\/tqwater.co.za\/?product=737simpletq80s45-38-inch-membrane-housing-4-element-450-psi"},"modified":"2026-03-25T12:25:58","modified_gmt":"2026-03-25T12:25:58","slug":"737simpletq80s45-38-inch-membrane-housing-4-element-450-psi","status":"publish","type":"product","link":"https:\/\/tqwater.co.za\/?product=737simpletq80s45-38-inch-membrane-housing-4-element-450-psi","title":{"rendered":"8040 FRP (6) Element RO Membrane Housing Reverse Osmosis 8Inch 450PSI"},"content":{"rendered":"<h2 data-path-to-node=\"16\">80S45 Series (450 PSI)<\/h2>\n<p data-path-to-node=\"17\"><i data-path-to-node=\"17\" data-index-in-node=\"0\">Heavy-duty housings for higher-pressure filtration and larger water volumes.<\/i><\/p>\n<h3 data-path-to-node=\"18\"><b data-path-to-node=\"18\" data-index-in-node=\"0\">Codeline 80S45-1 to 80S45-6<\/b><\/h3>\n<p data-path-to-node=\"19\"><b data-path-to-node=\"19\" data-index-in-node=\"0\">Description:<\/b> Premium 8-inch side-entry pressure vessels rated for 450 PSI. These units are built to withstand higher operating pressures, making them the preferred choice for high-recovery RO systems. Featuring the <b data-path-to-node=\"19\" data-index-in-node=\"215\">Quick Lock<\/b> head retention system, they allow for rapid membrane access, significantly reducing downtime during maintenance.<\/p>\n<p data-path-to-node=\"20\"><b data-path-to-node=\"20\" data-index-in-node=\"0\">Uses &amp; Applications:<\/b><\/p>\n<ul data-path-to-node=\"21\">\n<li>\n<p data-path-to-node=\"21,0,0\">High-recovery brackish water RO<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"21,1,0\">Wastewater recovery and recycling<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"21,2,0\">Boiler feed water treatment<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"21,3,0\">Large-scale commercial filtration systems<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"22\"><b data-path-to-node=\"22\" data-index-in-node=\"0\">Benefits:<\/b><\/p>\n<ul data-path-to-node=\"23\">\n<li>\n<p data-path-to-node=\"23,0,0\"><b data-path-to-node=\"23,0,0\" data-index-in-node=\"0\">Enhanced Pressure Rating:<\/b> Safely operates at 450 PSI for demanding applications.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"23,1,0\"><b data-path-to-node=\"23,1,0\" data-index-in-node=\"0\">Quick Lock System:<\/b> Tool-less head removal for faster membrane changes.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"23,2,0\"><b data-path-to-node=\"23,2,0\" data-index-in-node=\"0\">Multi-Porting Ready:<\/b> Flat octagonal exterior allows for easy vessel-to-vessel connection.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"23,3,0\"><b data-path-to-node=\"23,3,0\" data-index-in-node=\"0\">Maximum Durability:<\/b> UV-resistant coating and high-tensile fiberglass shell.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"24\"><b data-path-to-node=\"24\" data-index-in-node=\"0\">Compatible Systems:<\/b><\/p>\n<ul data-path-to-node=\"25\">\n<li>\n<p data-path-to-node=\"25,0,0\">All standard 8040 (8-inch) membrane elements<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"25,1,0\">Multi-stage RO purification skids<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"26\"><b data-path-to-node=\"26\" data-index-in-node=\"0\">Size &amp; Dimensions:<\/b><\/p>\n<ul data-path-to-node=\"27\">\n<li>\n<p data-path-to-node=\"27,0,0\"><b data-path-to-node=\"27,0,0\" data-index-in-node=\"0\">Diameter:<\/b> 8.0 inches<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,1,0\"><b data-path-to-node=\"27,1,0\" data-index-in-node=\"0\">Pressure Rating:<\/b> 450 PSI (31 Bar)<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,2,0\"><b data-path-to-node=\"27,2,0\" data-index-in-node=\"0\">Feed\/Concentrate Ports:<\/b> 1.5&#8243;, 2.0&#8243;, or 2.5&#8243; IPS Grooved (Standard: 1.5&#8243;)<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,3,0\"><b data-path-to-node=\"27,3,0\" data-index-in-node=\"0\">Permeate Ports:<\/b> 1&#8243; FNPT \/ 1.5&#8243; IPS Grooved<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,4,0\"><b data-path-to-node=\"27,4,0\" data-index-in-node=\"0\">Element Capacity:<\/b> * <b data-path-to-node=\"27,4,0\" data-index-in-node=\"20\">80S45-1:<\/b> 1 Element<\/p>\n<ul data-path-to-node=\"27,4,1\">\n<li>\n<p data-path-to-node=\"27,4,1,0,0\"><b data-path-to-node=\"27,4,1,0,0\" data-index-in-node=\"0\">80S45-2:<\/b> 2 Elements<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,4,1,1,0\"><b data-path-to-node=\"27,4,1,1,0\" data-index-in-node=\"0\">80S45-3:<\/b> 3 Elements<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,4,1,2,0\"><b data-path-to-node=\"27,4,1,2,0\" data-index-in-node=\"0\">80S45-4:<\/b> 4 Elements<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"27,4,1,3,0\"><b data-path-to-node=\"27,4,1,3,0\" data-index-in-node=\"0\">80S45-6:<\/b> 6 Elements (~260&#8243; length)<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<h2 data-path-to-node=\"2\"><b data-path-to-node=\"2\" data-index-in-node=\"0\">Selecting the Right Codeline 80S Pressure Vessel<\/b><\/h2>\n<p data-path-to-node=\"3\">Choosing the correct pressure vessel is critical for system safety, membrane longevity, and ease of maintenance. Use these three key factors to find your match.<\/p>\n<h3 data-path-to-node=\"4\"><b data-path-to-node=\"4\" data-index-in-node=\"0\">1. Pressure Rating: 300 PSI vs. 450 PSI<\/b><\/h3>\n<p data-path-to-node=\"5\">The pressure rating must exceed your system\u2019s maximum operating pressure, especially during cold-water start-ups when pressure naturally spikes.<\/p>\n<ul data-path-to-node=\"6\">\n<li>\n<p data-path-to-node=\"6,0,0\"><b data-path-to-node=\"6,0,0\" data-index-in-node=\"0\">Choose 300 PSI (80S30 Series):<\/b> For standard brackish water RO systems where operating pressures remain relatively low. These are the industry standard for most commercial and light industrial applications.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"6,1,0\"><b data-path-to-node=\"6,1,0\" data-index-in-node=\"0\">Choose 450 PSI (80S45 Series):<\/b> For high-recovery systems, high-TDS water sources, or wastewater recycling. If your system requires higher pump pressure to overcome osmotic resistance, the 450 PSI series provides the necessary safety margin.<\/p>\n<\/li>\n<\/ul>\n<h3 data-path-to-node=\"7\"><b data-path-to-node=\"7\" data-index-in-node=\"0\">2. Element Capacity: How many 8040 membranes?<\/b><\/h3>\n<p data-path-to-node=\"8\">The &#8220;dash&#8221; number in the SKU (e.g., -1, -3, -6) indicates how many 8-inch membranes fit inside a single housing.<\/p>\n<ul data-path-to-node=\"9\">\n<li>\n<p data-path-to-node=\"9,0,0\"><b data-path-to-node=\"9,0,0\" data-index-in-node=\"0\">1 to 2 Elements:<\/b> Best for compact skids or low-flow applications.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"9,1,0\"><b data-path-to-node=\"9,1,0\" data-index-in-node=\"0\">3 to 4 Elements:<\/b> The &#8220;sweet spot&#8221; for most medium-to-large industrial RO systems.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"9,2,0\"><b data-path-to-node=\"9,2,0\" data-index-in-node=\"0\">6 Elements:<\/b> Ideal for high-volume plants where minimizing the number of housings and manifold connections is a priority.<\/p>\n<\/li>\n<\/ul>\n<h3 data-path-to-node=\"10\"><b data-path-to-node=\"10\" data-index-in-node=\"0\">3. Port Size &amp; Flow Rates<\/b><\/h3>\n<p data-path-to-node=\"11\">The side-port size determines how much water can enter or exit the vessel without causing a significant pressure drop.<\/p>\n<ul data-path-to-node=\"12\">\n<li>\n<p data-path-to-node=\"12,0,0\"><b data-path-to-node=\"12,0,0\" data-index-in-node=\"0\">1.5&#8243; IPS Grooved (Standard):<\/b> Ideal for single-vessel setups or systems with moderate flow rates.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"12,1,0\"><b data-path-to-node=\"12,1,0\" data-index-in-node=\"0\">2.0&#8243; IPS Grooved (High-Flow):<\/b> Recommended for 4-to-6 element vessels or systems where multiple vessels are manifolded together. This larger port size reduces friction and improves energy efficiency.<\/p>\n<\/li>\n<\/ul>\n<hr data-path-to-node=\"13\" \/>\n<h3 data-path-to-node=\"14\"><b data-path-to-node=\"14\" data-index-in-node=\"0\">Quick Selection Table<\/b><\/h3>\n<table data-path-to-node=\"15\">\n<thead>\n<tr>\n<td><strong>Feature<\/strong><\/td>\n<td><strong>80S30 Series<\/strong><\/td>\n<td><strong>80S45 Series<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><span data-path-to-node=\"15,1,0,0\"><b data-path-to-node=\"15,1,0,0\" data-index-in-node=\"0\">Max Operating Pressure<\/b><\/span><\/td>\n<td><span data-path-to-node=\"15,1,1,0\">300 PSI (21 Bar)<\/span><\/td>\n<td><span data-path-to-node=\"15,1,2,0\">450 PSI (31 Bar)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"15,2,0,0\"><b data-path-to-node=\"15,2,0,0\" data-index-in-node=\"0\">Common Application<\/b><\/span><\/td>\n<td><span data-path-to-node=\"15,2,1,0\">Brackish Water RO<\/span><\/td>\n<td><span data-path-to-node=\"15,2,2,0\">High-Recovery \/ Wastewater<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"15,3,0,0\"><b data-path-to-node=\"15,3,0,0\" data-index-in-node=\"0\">Head Retention<\/b><\/span><\/td>\n<td><span data-path-to-node=\"15,3,1,0\">Retention Ring<\/span><\/td>\n<td><span data-path-to-node=\"15,3,2,0\">Quick Lock System<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"15,4,0,0\"><b data-path-to-node=\"15,4,0,0\" data-index-in-node=\"0\">Port Options<\/b><\/span><\/td>\n<td><span data-path-to-node=\"15,4,1,0\">1.5&#8243;, 2.0&#8243;, 2.5&#8243;<\/span><\/td>\n<td><span data-path-to-node=\"15,4,2,0\">1.5&#8243;, 2.0&#8243;, 2.5&#8243;<\/span><\/td>\n<\/tr>\n<tr>\n<td><span data-path-to-node=\"15,5,0,0\"><b data-path-to-node=\"15,5,0,0\" data-index-in-node=\"0\">Standard Temp<\/b><\/span><\/td>\n<td><span data-path-to-node=\"15,5,1,0\">-7\u00b0C to 49\u00b0C<\/span><\/td>\n<td><span data-path-to-node=\"15,5,2,0\">-7\u00b0C to 49\u00b0C<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":2415,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[243],"product_tag":[242],"class_list":["post-1185","product","type-product","status-publish","has-post-thumbnail","product_cat-frp-membrane-housings","product_tag-frp-ro-membrane-housing","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/product\/1185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1185"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/media\/2415"}],"wp:attachment":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1185"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=1185"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1185"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}