{"id":1170,"date":"2025-06-17T04:58:50","date_gmt":"2025-06-17T04:58:50","guid":{"rendered":"https:\/\/tqwater.co.za\/?product=722simpletqmro-tml20d-4008-inch-reverse-osmosis-membrane-toray-8040"},"modified":"2026-03-22T03:10:57","modified_gmt":"2026-03-22T03:10:57","slug":"722simpletqmro-tml20d-4008-inch-reverse-osmosis-membrane-toray-8040","status":"publish","type":"product","link":"https:\/\/tqwater.co.za\/?product=722simpletqmro-tml20d-4008-inch-reverse-osmosis-membrane-toray-8040","title":{"rendered":"8&#8243;8040 Industrial Brackish Water Membrane Legacy\/Obsolete (10000GPD)G-Series (Low Pressure)"},"content":{"rendered":"<table dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\">\n<colgroup>\n<col width=\"131\" \/>\n<col width=\"167\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>Feature<\/td>\n<td>ID: 1170 (TMG20)<\/td>\n<td>\n<div>\n<div>ID: 1173 (TM720)<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Series<\/td>\n<td>G-Series (Low Pressure)<\/td>\n<td>\n<div>\n<div>7-Series (Standard BW)<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Focus<\/td>\n<td>Energy Efficiency<\/td>\n<td>Water Purity<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Typical Pressure<\/td>\n<td>~115 PSI<\/td>\n<td>~225 PSI<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Modern Replacement<\/td>\n<td>TMG20D-400 (ID: 1168)<\/td>\n<td>\n<div>\n<div>TM720D-400 (ID: 1169)<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p data-path-to-node=\"55\">legacy Toray membranes are kept in stock specifically for older industrial systems that require exact matching of original flow specifications. While modern &#8220;D-Series&#8221; membranes are more efficient, these &#8220;Obsolete&#8221; models are often necessary for systems with fixed-speed pumps or specific pressure-drop requirements that cannot easily be re-calibrated.<\/p>\n<p data-path-to-node=\"56\"><b data-path-to-node=\"56\" data-index-in-node=\"0\">Uses &amp; Applications:<\/b><\/p>\n<ul data-path-to-node=\"57\">\n<li>\n<p data-path-to-node=\"57,0,0\"><b data-path-to-node=\"57,0,0\" data-index-in-node=\"0\">Legacy System Repairs:<\/b> Direct replacement for systems built between 2010\u20132020.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"57,1,0\"><b data-path-to-node=\"57,1,0\" data-index-in-node=\"0\">Specific Pump Matching:<\/b> For systems where modern high-flux membranes might cause pump cavitation.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"58\"><b data-path-to-node=\"58\" data-index-in-node=\"0\">Benefits:<\/b><\/p>\n<ul data-path-to-node=\"59\">\n<li>\n<p data-path-to-node=\"59,0,0\"><b data-path-to-node=\"59,0,0\" data-index-in-node=\"0\">Proven Compatibility:<\/b> Eliminates the need for system re-engineering.<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"59,1,0\"><b data-path-to-node=\"59,1,0\" data-index-in-node=\"0\">28-mil Feed Spacer:<\/b> Features the original wider feed spacer for better handling of high-turbidity water.<\/p>\n<\/li>\n<\/ul>\n<p data-path-to-node=\"60\"><b data-path-to-node=\"60\" data-index-in-node=\"0\">Size &amp; Dimensions:<\/b><\/p>\n<ul data-path-to-node=\"61\">\n<li>\n<p data-path-to-node=\"61,0,0\"><b data-path-to-node=\"61,0,0\" data-index-in-node=\"0\">Capacity:<\/b> ~8,000\u201310,000 GPD<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"61,1,0\"><b data-path-to-node=\"61,1,0\" data-index-in-node=\"0\">Length:<\/b> 1016 mm (40&#8243;)<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"61,2,0\"><b data-path-to-node=\"61,2,0\" data-index-in-node=\"0\">Diameter:<\/b> 201 mm (8&#8243;)<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"61,3,0\"><b data-path-to-node=\"61,3,0\" data-index-in-node=\"0\">Weight:<\/b> ~15.00 kg<\/p>\n<\/li>\n<li>\n<p data-path-to-node=\"61,4,0\"><b data-path-to-node=\"61,4,0\" data-index-in-node=\"0\">Housing:<\/b> Requires 8040 Industrial Pressure Vessel.<\/p>\n<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<table dir=\"ltr\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" data-sheets-root=\"1\" data-sheets-baot=\"1\">\n<colgroup>\n<col width=\"100\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/>\n<col width=\"100\" \/><\/colgroup>\n<tbody>\n<tr>\n<td>ID<\/td>\n<td>Series Type<\/td>\n<td>GPD Rating<\/td>\n<td>\n<div>\n<div>Key Performance Note<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1167<\/td>\n<td>Sea Water (SW)<\/td>\n<td>9,000<\/td>\n<td>\n<div>\n<div>Quality: 99.8% Rejection \/ Boron Removal<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1171<\/td>\n<td>Sea Water (SW)<\/td>\n<td>8,500<\/td>\n<td>\n<div>\n<div>Flow: Higher permeate delivery for SWRO<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1168<\/td>\n<td>Brackish (BW)<\/td>\n<td>12,100<\/td>\n<td>\n<div>\n<div>Flow: G-Series Ultra-Low Pressure energy saver<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1169<\/td>\n<td>Brackish (BW)<\/td>\n<td>11,000<\/td>\n<td>\n<div>\n<div>Standard: Balanced rejection\/flow for general use<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1172<\/td>\n<td>Brackish (BW)<\/td>\n<td>10,000<\/td>\n<td>\n<div>\n<div>Fouling: L-Series for waste\/surface water<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1170<\/td>\n<td>Legacy (BW)<\/td>\n<td>10,000<\/td>\n<td>\n<div>\n<div>G-Series Obsolete: Legacy Low Pressure replacement<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>1173<\/td>\n<td>Legacy (BW)<\/td>\n<td>10,000<\/td>\n<td>\n<div>\n<div>7-Series Obsolete: Legacy Purity replacement<\/div>\n<\/div>\n<\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":2404,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[436],"product_tag":[],"class_list":["post-1170","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-large-scale-reverse-osmosis-membranes-800012000gpd","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/product\/1170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1170"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=\/wp\/v2\/media\/2404"}],"wp:attachment":[{"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1170"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=1170"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=1170"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/tqwater.co.za\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=1170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}